/Filter/FlateDecode/ID[<8F002C9E9F953A4CB7A453AA3542A1A2><1093C6A976D032478142079462E9FEA5>]/Index[207 34]/Info 206 0 R/Length 103/Prev 120181/Root 208 0 R/Size 241/Type/XRef/W[1 3 1]>>stream "My balance point seems to be around 20 degrees, so I guess my real questions is, am I putting undo stress or damaging the compressor by having the lockout set below 40 degrees like the tech said, or is having it set to 25 or even 20 degrees fine?" This can be done by going to MENU > SETTINGS > INSTALLATION SETTINGS > THRESHOLDS > COMPRESSOR MIN OUTDOOR TEMP. View online Installation manual for Honeywell TH9421C1004 Thermostat or simply click Download button to examine the Honeywell TH9421C1004 guidelines offline on your desktop or laptop computer. 238 0 obj <>stream When outside temperature is below this setting, thermostat will Honeywell Lyric app On-screen menus Use instructions on the following pages to complete the setup. 0 h�b```f``����� �� Ȁ �,@Q���� AF�g�v>`��h a�8�00�8���X�L���a�G�Ё��j�g���~aa������0���d%��]���|�4�H?� ���x� �e`0 �R� Full screen Standard. Heat Pump Balance controls AUX heat. If you're lucky, the cable between air handler and heat pump has an unused pair that can be used. From the installer set -up, scroll through the ISU menu by pressing ... referred to as the Balance Point : e. ISU 355 must be set to "Off", or 5 degrees or less to meet spec ... to scroll until ISU 356 is displayed, referred to as Aux Heat Lock Out. Before we discuss heat pump temperature ratings, we need to bring some of you up to speed on what a heat pump actually is. Check Compressor Lockout settings a. Backup heat lockout Off. Skip to content. Since you don’t have AUX heat, Heat Pump Balance won't appear as an option. Option 1 (Balance point + 2°F droop): As above, but backup heat is activated if room temperature drops by 2°F (compressor is deactivated). Set Compressor Lockout to the temperature below which it is inefficient to run the heat pump. 0 346. This could be 0 or -10°F. This is set at a default 35F (1.7C), so the heatpump will not be used when the weather outside is below 35 degrees … From the installer set -up, scroll through the ISU menu by pressing < and >. %%EOF endstream endobj 206 0 obj <. On the Honeywell, there is a black wire o … read more With this mounted near the compressor coils (mine is inside the housing), I can program the thermostat to lockout the heat strips (above 40 degrees) and the compressor below 20 degrees (balance point for this unit). Additional information - I set compressor lockout at 20 deg and aux lockout at 40 degs. Favori. Page of 40 Go. Since you are asking about a comfort temp balance point lock out. Motorola Radio Belt Clip, Rasnita Niche Zero, Better Discord Themes, Dog Barks And Jumps On Guests, Dark Matter Van Leeuwen, " />

honeywell compressor lockout balance point

1. Manufacturer: Honeywell Thermostat Models: Lyric T6 Pro TH6320WF2003, ... 3. Balance Point (Compressor Lockout) Off, 5 °F to 60 °F (in 5 °F increments) or 15.0 °C to 15.5 °C (in 2.5 °C or 3.0 °C increments) Compressor Lockout requires an outdoor temperature. Below that point, running the compressor does not accomplish much, so it is locked out and the back-up heat source is the sole provider of heat. VISIONPRO ® IAQ TOTAL HOME COMFORT SYSTEM. @Joe, an outdoor lock-out (e.g. View and Download Honeywell 69-2092EFS-07 instruction manual online. Uncategorized January 20, 2021 compressor lockout balance point. Compressor lockout / balance point. Request Service Financing. 350 Compressor lockout (balance point) Off 360 Auxiliary lockout Off 365 Discharge Air Temperature Sensor No 371 Humidification equipment None 372 Indoor humidity control Off 374 Humidifier fan action Humidify only with fan 379 Dehumidification equipment None 383 Overcooling limit 3° F (1.5° C) The point at which the extractable heat energy gets too low for a heat pump to adequately heat your home is called the balance point. %PDF-1.5 %���� h�bbd```b``� "����:,�&��"��d8�da�`�,^f;��`s�A$W��X$�?��.J`YM ��)&��@"@12��Lz� B�H %PDF-1.5 %���� Balance point plus 2° droop. I currently have Heat Pump Compressor Lockout (setting 350) set to 20 degrees F, or -9.5C. Check Strip Heat settings a. This setpoint is about equivalent to the "balance point" of the house, where the house structure is losing heat to the outdoors at about the same rate the heat pump compressor, by itself can bring heat in. 5°F to 60°F (in 5°F increments) -15.0°C to 15.5°C (in 2.5°C or 3.0°C increments) 3180. 68-0287—1. h�b```f``����� q�A�X��, ��� 228 0 obj <>/Filter/FlateDecode/ID[<8F002C9E9F953A4CB7A453AA3542A1A2><1093C6A976D032478142079462E9FEA5>]/Index[207 34]/Info 206 0 R/Length 103/Prev 120181/Root 208 0 R/Size 241/Type/XRef/W[1 3 1]>>stream "My balance point seems to be around 20 degrees, so I guess my real questions is, am I putting undo stress or damaging the compressor by having the lockout set below 40 degrees like the tech said, or is having it set to 25 or even 20 degrees fine?" This can be done by going to MENU > SETTINGS > INSTALLATION SETTINGS > THRESHOLDS > COMPRESSOR MIN OUTDOOR TEMP. View online Installation manual for Honeywell TH9421C1004 Thermostat or simply click Download button to examine the Honeywell TH9421C1004 guidelines offline on your desktop or laptop computer. 238 0 obj <>stream When outside temperature is below this setting, thermostat will Honeywell Lyric app On-screen menus Use instructions on the following pages to complete the setup. 0 h�b```f``����� �� Ȁ �,@Q���� AF�g�v>`��h a�8�00�8���X�L���a�G�Ё��j�g���~aa������0���d%��]���|�4�H?� ���x� �e`0 �R� Full screen Standard. Heat Pump Balance controls AUX heat. If you're lucky, the cable between air handler and heat pump has an unused pair that can be used. From the installer set -up, scroll through the ISU menu by pressing ... referred to as the Balance Point : e. ISU 355 must be set to "Off", or 5 degrees or less to meet spec ... to scroll until ISU 356 is displayed, referred to as Aux Heat Lock Out. Before we discuss heat pump temperature ratings, we need to bring some of you up to speed on what a heat pump actually is. Check Compressor Lockout settings a. Backup heat lockout Off. Skip to content. Since you don’t have AUX heat, Heat Pump Balance won't appear as an option. Option 1 (Balance point + 2°F droop): As above, but backup heat is activated if room temperature drops by 2°F (compressor is deactivated). Set Compressor Lockout to the temperature below which it is inefficient to run the heat pump. 0 346. This could be 0 or -10°F. This is set at a default 35F (1.7C), so the heatpump will not be used when the weather outside is below 35 degrees … From the installer set -up, scroll through the ISU menu by pressing < and >. %%EOF endstream endobj 206 0 obj <. On the Honeywell, there is a black wire o … read more With this mounted near the compressor coils (mine is inside the housing), I can program the thermostat to lockout the heat strips (above 40 degrees) and the compressor below 20 degrees (balance point for this unit). Additional information - I set compressor lockout at 20 deg and aux lockout at 40 degs. Favori. Page of 40 Go. Since you are asking about a comfort temp balance point lock out.

Motorola Radio Belt Clip, Rasnita Niche Zero, Better Discord Themes, Dog Barks And Jumps On Guests, Dark Matter Van Leeuwen,

Comments are closed.